⚠️ California Proposition 65 Warning : Some products sold on this website may expose you to chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information, visit www.P65Warnings.ca.gov.
The Murphy 761APH-60-12 Tattletale is a reliable device designed for use in distributor ignition and diesel engines. It offers a time delay lockout feature for Swichgage contacts during start-up, making it an essential component for efficient engine management.
This 12-volt model is engineered to provide a 60-second time delay, ensuring optimal performance in critical situations. The Tattletale is equipped with a manual indicating reset type, which adds to its usability and functionality. Its robust design breaks and makes circuits when tripped, providing enhanced safety and reliability in engine operation.
Key Features:
Designed for distributor ignition or diesel engines, ensuring broad compatibility.
Time delay lockout of Swichgage contacts on start-up, enhancing operational efficiency.
Manual indicating reset type for straightforward operation and quick reset capability.
12-volt model with a 60-second time delay, ideal for various engine applications.
NCH and NOH control circuit output contacts rated for 10 amps 24V, ensuring reliable performance.
Features a "hot" output in latched and tripped positions for effective circuit management.
Includes a 14 amp fuse and carries the CE mark for compliance with European safety standards.
The Murphy 761APH-60-12 Tattletale is an excellent choice for engine operators seeking a dependable solution for ignition and diesel engine management. Its features enhance safety and efficiency, making it suitable for both commercial and personal applications. With its robust construction and reliable performance, this device is ideal for anyone needing precise control over ignition systems.
Yes, we offer free standard shipping on all orders within the United States.
When will I receive my item?
Domestic orders typically arrive within 3-5 business days. Delivery times are estimated and may vary depending on your location, weather conditions, or other unforeseen factors.
Can I change or return my item?
We hope you love your purchase, but if you need to make a change or return your item, we’ve got you covered! You can initiate a return or exchange within 30 days of receiving your order. Please ensure the product is in its original condition and packaging. For more information on our return policy, please visit our Returns & Exchanges page.
Frequently Asked Questions
Q: What is the voltage of the Murphy 761APH-60-12 Tattletale?A: The voltage is twelve volts. This model is specifically designed for use with distributor ignition or diesel engines.
Q: Does the Murphy 761APH-60-12 have a time delay feature?A: Yes, it has a time delay lockout of sixty seconds. This feature applies only on start-up, allowing for delayed or immediate trips on shutdown.
Q: What type of contacts does the Murphy 761APH-60-12 use?A: It uses normally closed and normally open contacts. These contacts are rated for ten amps at twenty-four volts.
Q: What is the purpose of the Murphy 761APH-60-12 Tattletale?A: This device is used for monitoring distributor ignition or diesel engines. It breaks and makes circuits when tripped, ensuring proper engine operation.
Q: How do I reset the Murphy 761APH-60-12 Tattletale?A: It features a manual indicating reset type. You will need to manually reset it after it has been tripped.
Q: Can the Murphy 761APH-60-12 be used for both diesel and ignition engines?A: Yes, it is compatible with both types of engines. This versatility makes it suitable for various applications.
Q: What is the latch type of the Murphy 761APH-60-12?A: The latch type is energize to trip. This means that the device requires power to activate the trip mechanism.
Q: How is the Murphy 761APH-60-12 wired for shutdown trips?A: It can be wired for either delayed or immediate trips on shutdown. This flexibility allows for customization based on user needs.
Q: What is included with the Murphy 761APH-60-12?A: A fourteen amp fuse is included with the device. This fuse ensures protection against overcurrent situations.
Q: Is the Murphy 761APH-60-12 certified for safety?A: Yes, it carries the CE mark. This indicates compliance with European safety standards.
Q: How do I maintain the Murphy 761APH-60-12 Tattletale?A: Regularly check the wiring and connections for wear and tear. Ensure that the unit is kept free from moisture and debris.
Q: Is there a warranty for the Murphy 761APH-60-12?A: Yes, the product typically comes with a warranty. Please check with the manufacturer for specific warranty details.
Q: What should I do if the Murphy 761APH-60-12 arrives damaged?A: If it arrives damaged, contact customer support immediately. They will assist you with return and replacement options.
Q: How do I install the Murphy 761APH-60-12 Tattletale?A: Installation requires basic electrical knowledge. Follow the wiring diagrams provided in the manual for proper installation.
Q: Can I use the Murphy 761APH-60-12 in a marine application?A: It is not specifically designed for marine applications. Use caution and consult with a professional if considering installation in such environments.
Q: What is the best way to store the Murphy 761APH-60-12?A: Store it in a cool, dry place away from moisture and extreme temperatures. This will help maintain its functionality and longevity.